Changes between Version 5 and Version 6 of HetProcedures/FPAHardware


Ignore:
Timestamp:
Jun 12, 2019 4:15:27 PM (5 years ago)
Author:
admin
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • HetProcedures/FPAHardware

    v5 v6  
    1010can only be run on the telescope and these must be run once the FPA
    1111is back on the PFIP in order to fully characterize the hardware.
     12
     13=== From George Damm's test notes ===
     14
     15There are actually 2 different test scenarios for checking things during a FPA takedown, 1) FPA on ground and 2) FPA on telescope.  The differences are due to missing pieces of equipment. When the FPA is on the ground, both the BIB and the HPF ACQ cameras are not present, they are mounted on the assembly with the IHMP.
     16
     17The collision avoidance hall-effect sensors in the carriages of the Guider1 and 2 and WFS1 and 2 cannot be tested in an automated fashion since collision avoidance routines will keep them from getting close enough to each other.  The carriages must be moved by hand while watching for the pertinent bits to be triggered.
     18
     19I will list what I have for a test procedure in a slightly different format, keeping like functionality together.
     20
     211) FPA on Telescope
     22
     23Taking images on all cameras will verify the functionality of the single board computers (if they are used)
     24
     25  1. Verify functioning images on Guider1, Guider2, WFS1, WFS2,ACQ Cam, PV Camera, CWFS Camera, BIB Camera, HPF ACQ camera
     26
     27  2. Verify functioning probes by moving them to Beginning of Range then to End of Range and then back again.  Record carriage and probe arm motor current for post processing on Guider1, Guider2, WFS1, WFS2
     28
     29  3. Verify PFIP Shutter motion
     30
     31  4. Move to all filter positions for Guider1, Guider2, ACQ Cam
     32
     33  5. Verify function of ACQ Cam focus
     34
     35  6. Move the three pneumatic actuators to both positions and verify, ACQ Cam fold mirror, PV/CWFS fold mirror, PV/CWFS selector
     36
     37  7. Check dither mechanism
     38
     39
     402) FPA on ground
     41
     42Same as above, remove test of BIB and HPF ACQ Cameras
     43
     44=== From Jim Fowler's notes ===
     45
     46Requirements for testing PFIP hardware in the FPA.
     4710 Jun 2019
     48
     49This is a hardware test only. Alignment tests will be done by the night staff
     50
     51Need to define the
     52
     53  mechanism tested,
     54
     55  commands sent,
     56
     57  monitor point,
     58
     59  success criteria,
     60
     61  restrictions - prior tests, other mechanisms in particular locations/starting criteria
     62
     63  ground/air test only?
     64
     65Tests
     66
     67  verify communications with SBC systems
     68
     69  move ACQ camera in/out
     70
     71  expose ACQ cam
     72
     73  operate filters
     74
     75  for Guider1, Guider2, WFS1, WFS2
     76
     77    operate camera
     78
     79    verify image
     80
     81  operate filters
     82
     83    verify sensors
     84
     85  operate probes full range
     86
     87    test limits
     88
     89    measure currents
     90
     91  check PV camera
     92
     93  check CFWS camera
     94
     95    move in/out
     96
     97    check indicators
     98
     99    take image
     100
     101  check BIB camera
     102
     103    take image
     104
     105  operate shutter, visual check on the ground
     106
     107
     108Should we test for interactions between devices?
     109
     110
     111=== Test Requirements ===
    12112
    13113Below is a preliminary list of tests to verify the FPA hardware. The test