Changes between Version 70 and Version 71 of HetProcedures/RA/overview
- Timestamp:
- Nov 18, 2016 1:39:14 AM (7 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
HetProcedures/RA/overview
v70 v71 4 4 5 5 === suggested order of OPS procedure. === 6 * /opt/het/hetdex/src/tcs/trunk/camra/testing/pfeiffer.py 7 sometimes you have to execute it several times to get the prompt[[BR]] 8 on 1[[BR]] 9 on 2[[BR]] 10 * check instruments temperatures 11 * document VIRUS enclosure temperatures 12 * take lrs2 and virus test cals 13 * do test move of the guide probes (home4 or home5) 14 * check lrs2 vacuum pressure[[BR]] 15 pressure 1[[BR]] 16 pressure 2[[BR]] 6 * run 7 {{{ syscmd -l 'get_cryo_pressure( update_state="true" )' }}} 8 to check LRS2 VG pressure. If got 999999 that means that VG need to be 9 enabled and one need to wait 15 minutes before read out pressure 17 10 * turn off VG and ion pump. 18 11 Important!!!! please leave LRS2*-VacuumGauge on on APC GUI. … … 22 15 syscmd -l 'enable_pressure_gauges()' # should be run RA in the morning 23 16 }}} 17 * check instruments temperatures 18 * take lrs2 and virus test cals 19 * document VIRUS enclosure temperatures 20 * do test move of the guide probes (home4 or home5) 24 21 * take any long cals that can be done 25 22