    7474* Check lrs2 vacuum pressure
    7575
    76 Turn on the vacuum gauge in the apcGui. Run the pfeiffer.py scrWFUCommissioning/wiki/ipt.
    77 (In case of error try to run the script second time about 1 min
    78 after turning of vacuum gage):Take twilight spectra
    79 
    80     First any imaging cameras
    81     LRS2 spectra
    82 
    83         /opt/het/hetdex/src/tcs/trunk/camra/testing/pfeiffer.py
    84 Note: Sometimes you have to enter this several times before you get a prompt back.
    85 Then enter the following commands:
    86 {{{
    87         on 1
    88         on 2
    89         wait about 15 minutes for the gauge to warm up
    90         pressure 1
    91         pressure 2
    92         exit off
    93 }}}
    94 
    95 
    96 Here is a complete run:
    97 {{{
    98 [sco@lrs2 ~]$ /opt/het/hetdex/src/tcs/trunk/camra/testing/pfeiffer.py
    99 Pfeiffer Vacuum; TPG262 ActiveLine DualGauge Controller
    100 Example RS-232 Serial Control Script
    101 -----------------------------------------------------------
    102 By: Taylor S. Chonis, tschonis@astro.as.utexas.edu
    103 The University of Texas at Austin, Dept. of AstronomyWFUCommissioning/wiki/
    104 
    105 -----------------------------------------------------------
    106 
    107 Detected Sensors (1,2): PKR,PKR
    108 
    109 Pressure Units: TORRWFUCommissioning/wiki/
    110 Sensor 1 Setup Complete
    111 Sensor 2 Setup Complete
    112 MENU:
    113     Command:          Function:
    114     --------          ---------
    115     > help            Display this MenuWFUCommissioning/wiki/
    116 
    117     > on 1            Turn Sensor 1 ON
    118     > on 2            Turn Sensor 2 ON
    119     > off 1           Turn Sensor 1 OFF
    120     > off 2           Turn Sensor 2 OFF
    121     > status          Display Sensor Power Status
    122     > pressure 1      Display Sensor 1 Pressure
    123     > pressure 2      Display Sensor 2 Pressure
    124     > exit off        Exit; Both Sensors switched OFFWFUCommissioning/wiki/
    125 
    126     > exit            Exit; Sensor Status UnchangedNigWFUCommissioning/wiki/
    127 >>  on 1
    128 OK (Allow warm up time)
    129 >> on 2
    130 OK (Allow warm up time)
    131  WAIT 15 minutes    (until 00:44UT)
    132 >> pressure 1
    133 Pressure OK; 1.3500E-05
    134 >> pressure 2
    135 Pressure OK; 2.2900E-05
    136 >> exit off
    137 }}}
     76run {{{ syscmd -l 'get_cryo_pressure( update_state="true" )' }}}
     77      to check LRS2 VG pressure. If got 999999 that means that VG need to be
     78      enabled and one need to wait 15 minutes before read out pressure
    13879
    13980* Test guide probe motions