Changes between Version 77 and Version 78 of HetProcedures/RA/overview


Ignore:
Timestamp:
Dec 3, 2016 10:14:12 PM (7 years ago)
Author:
sir
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • HetProcedures/RA/overview

    v77 v78  
    4747         * Cryo temps should be close to -168
    4848
     49* Check lrs2 vacuum pressure
    4950
     51run {{{ syscmd -l 'get_cryo_pressure( update_state="true" )' }}} to check LRS2 VG pressure. If got 999999 that means that VG need to be enabled and one need to wait 15 minutes before read out pressure
    5052
    5153* Record VIRUS enclosure temperatures from "VIRUS Environment" tab in TCS gui
     
    7173The following check of LRS2 should take about 11 minutes to complete:  [[br]]
    7274{{{ $HET_SRC_ROOT/integration/cal.py -i lrs2 -l lamp3a -L 1 -c lamp5b -C 1 -b 1 -o 9990 | & tee -a lrs-cal.201612DD.log }}}
    73 
    74 * Check lrs2 vacuum pressure
    75 
    76 run {{{ syscmd -l 'get_cryo_pressure( update_state="true" )' }}}
    77       to check LRS2 VG pressure. If got 999999 that means that VG need to be
    78       enabled and one need to wait 15 minutes before read out pressure
    7975
    8076* Test guide probe motions