Changes between Version 2 and Version 3 of HetProcedures/TO/pointingtest
- Timestamp:
- Dec 7, 2019 9:02:50 AM (4 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
HetProcedures/TO/pointingtest
v2 v3 8 8 === 4 Point Test === 9 9 10 Run trajectories at the cardinal points. Select objects that are close to the center11 of the track erfor best results. The cardinal points are10 Run trajectories at the cardinal points. Select objects (e.g., stars from F9 catalog, set up on the IHMP center position IFU=000) that are close to the center 11 of the track (within 3 minutes) for best results. The cardinal points are 12 12 13 13 || Azimuth || Dec || || … … 17 17 || 294.458 || 38.478 || west trajectory || 18 18 19 Record the actual true azimuth of the structure and the !Ra/Dec offsets required to get the object 20 to the center of the field. 19 Store images on the ACQ camera and all probes during the test. Assure good focus, un-saturated target star, etc. On each target, record the actual true azimuth of the structure, the parallactic angle, and the X,Y offsets required to get the object to the correct position on the ACQ camera. 21 20 22 21 The north and south trajectories should require close to the same offset as should the 23 22 east and west trajectories. The north/south Ra correction should be similar to the east/west 24 Dec correction and it should be applied to the azimuth correction 23 Dec correction and it should be applied to the azimuth correction, while the north/south Dec should 25 24 be similar to the east/west Ra and is applied to the elevation correction. 26 25