Changes between Version 6 and Version 7 of NightOperations/Commissioning/Plans/20161218
- Timestamp:
- Dec 18, 2016 3:27:22 AM (7 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
NightOperations/Commissioning/Plans/20161218
v6 v7 30 30 * Setup on IHMP 31 31 * Center up both guide probes and start guiding on one of the guiders 32 * Set Exposure times for CWFS, WFS1 and WFS2 to about 5 seconds to assist in centering. 32 33 * Offset to CWFS using {{{syscmd -T 'offset_trajectory(dx_ang=-5.5, dy_ang=0.0, adjust_probes="true")'}}} 33 34 * Tweak up the position on the IHMP using further offset_trajectory commands. … … 35 36 * Null out focus on WFS1. NOTE: WFS1 seems to perform better than WFS2 at the edges of the track 36 37 * Start metrology loop and Activate the loop on WFS1. 38 * Increase the exposure time for the CWFS, WFS1 and WFS2 to greater than 20 seconds for data taking. 37 39 * Hit "store images" and "Start Metrology Loop" for GC1, GC2, WFS1, WFS2, TT, CWFS, DMI (although there are no images for DMI) 38 40 * Run until the end of the track.