8 | | * Turn off the DMIFocus option in AOA software |
9 | | * Move the focus to the starting DMI position (for winter probably 26.2115, summer 26.210) |
10 | | * To measure the DMI position go to the DMI on the VNC and zoom in on the plot until you can get a good DMI value out to 5 digits |
11 | | * Stack at the starting position (2 times on each side but end always on the same side) |
12 | | * Run a measurement curve on the HEFI. |
| 8 | * Turn off the dmifocus option in AOA software by toggling the command "dmifocus" |
| 9 | * Move the MARS focus stage to the starting DMI position (for winter probably 26.2115, summer 26.210)[[BR]] |
| 10 | |
| 11 | NOTE: To measure the DMI position go to the DMI on the VNC and zoom in on the plot until you can get a good DMI value out to 5 digits[[BR]] |
| 12 | |
| 13 | * Stack (2 times on each side but end always on the same side) but do not change MARS focus |
| 14 | * Run a measurement curve on the HEFI. If you get a bad looking curve try adjusting the exposure time, starting hefi focus position, running it again or as a last resort restarting HEFI. |