Changes between Version 63 and Version 64 of NightOperations/Commissioning/pFPA


Ignore:
Timestamp:
Oct 15, 2023 8:46:17 AM (7 months ago)
Author:
stevenj
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • NightOperations/Commissioning/pFPA

    v63 v64  
    6868[[br]]
    6969
    70 === Maybe get WFS1/2 with FCU lamp too, just to double-checked?? ===
    71   * Qth, red guide, 15s exposures on WFS1/WFS2; probes at home5 (not evenly illuminated, but can see circles)
    72 
     70=== Check WFS1/2 aperture spots with FCU lamp too, to check for any changes ===
     71  * Qth, red guide, 15s exposures on WFS1/WFS2; probes at home5
     72  * Save some images, use ds9 to get the center of the selected spot by eye (compare before and after). If there is a big change, contact Hanshin to update the apertures on the WFS processing pipeline (required before WFS are useable!)
    7373
    7474[[Image(wf1.jpeg, 300px)]]
     
    8686  * Notify Joe Ninan that the images have been saved and what the image name is.
    8787  * Measure the position for the center of the HPFACAM direct field:
    88       * Use ds9 measure the center of both CFB: this can be done with circle markers and then looking at the marker info. You will need to play with the scale to get the off axis one to look like a circle due to the coma at that position.
     88      * Use ds9 measure the center of both CFB: this can be done with circle markers (145 pixel radius is good for both) and then looking at the marker info. You will need to play with the scale to get the off axis one to look like a circle due to the coma at that position.
    8989      * be sure the last results are saved under ”old results on the wiki”
    9090      * update the [wiki:HetProcedures/RA/markers wiki values] for both CFB centers.
    9191      * Note how much rotation is required from the central one to the new off-axis position and this is the delta angle to report to the TCS team.
    92       * Ask Amy and Nathan to update the TO setup scripts; inform the software team of the new position for the marker file.
     92      * Ask Amy and Nathan to update the TO setup scripts.
    9393      * This should be the CRPIX value for the HPFACAM as well so these numbers should be given to the software team for updating in TCS (note these are in units of binned pixels).
     94
     95[[Image(hpfacm.jpeg, 300px)]]
     96
     97[[br]]
    9498
    9599[[br]]